The FAC-2100 controller basic root ordering code is:
FAC2100-DC28DC-28-C
This describes a unit that accepts DC input power, provides 28V on the axillary power output terminals, uses a standard relay board (reference Relay Outputs for more information), and has circular connectors.
...
To change the installed relay option, append a -R to the end of the root ordering code. In addition, append three digits where each digit is an 'A' or a 'D'. The last three digits indicate if relay #2, #3, and #5 (respectively) should be AC (A) or DC (D).
FAC2100-DC28DC-28-C-RX2X3X5, where:
- Xn is either an 'A' or 'D' and specifies if the output is AC or DC, and
- n in Xn is the solid state relay number.
For example:
- FAC2100-DC-DC2828-C-RDDA specifies that there should be DC solid relays for relay #2 and #3 and an AC solid state relay for Relay #5.