Version Details
Release Date: 6/14/2011
Version: v4.5.230
Download Links
Chameleon.4.5.230.$cc (2.8 MB)
NIM2_Release-kernel.4.5.230.bin (2.1 MB)
NIM2.4.5.230.$cc (2.3 MB)
Note: These files are included in the Design Pad and/or Schema Viewer v4.5.230 2xx installation. They can be found in \Program Files\Fairmount Automation\<PROGRAM NAME> folder (where <PROGRAM NAME> is 'Design Pad G4' or 'Schema Viewer G4').
Download Contents
These files contains the firmware v4.5.230 for Chameleon hardware. Select from the following software items:
Firmware for all modules except NIM-2: Chameleon.4.5.230.$cc
Firmware for NIM-2: NIM2_Release-kernel.4.5.230.bin (RAW) or NIM2.4.5.230.$cc
Installation Instructions:
Non-NIM-2 Modules:
- Remove any NIM-2 active boards from the node
- Start Design Pad or Schema Viewer
- Choose 'Firmware Update' from the Communications Menu
- Align the IR wand to the right-most module
- Select the Chameleon.4.5.230.$cc file when requested
- Follow the on-screen instructions to complete the download
- Restore any NIM-2 active boards back into the node
Updating NIM-2 Modules from versions prior to v4.5.230:
- Ensure the NIM-2(s) are configured (IP address loaded, etc.) to be on the same network as the computer that is performing the update.
- On a computer that has v4.5.230 Design Pad or Schema Viewer installed, browse to the \Program Files\Fairmount Automation\Design Pad G4 or \Program Files\Fairmount Automation\Schema Viewer G4 Folder.
- Edit the nmupdater.bat file by right-clicking on the file and selecting edit.
- Set the BASEIP (first three octets of IP address) and IPs (last octet of IP) variables to the addresses of the NIM-2 to update.
- Set the FIRMWARE variable to the location of the *.bin firmware update file. For v4.5.230 this is the NIM2_Release-kernel.4.5.230.bin file.
- Select File and Save, then File and Exit from the editor.
- Double-click on the nmupdater.bat file to start the update process. Do not close the command prompt window until the "Done. You may close this window now." message appears.
Updating NIM-2 Modules from versions v4.5.230 and higher:
- Ensure the NIM-2(s) are configured (IP address loaded, etc.) to be on the same network as the computer that is performing the update.
- Start Design Pad or Schema Viewer v4.5.230 or higher.
- Select 'Use Ethernet' from the Communications Menu.
To Update a Single NIM-2:
a. Open the Workspace and HWI associated with the NIM-2 to update.
b. Choose 'Firmware Update' from the Communications Menu
c. When prompted, select the NIM2_Release-kernel.4.5.230.bin or NIM2.4.5.230.$cc file
d. Follow the on-screen instructions to complete the download
To Update Multiple NIM-2s:
a. Open the Workspace associated with the NIM-2 to update.
b. Right-click on the word 'Workspace' in the Workspace window and select Update Firmware (All Ethernet Hardware) from the Communications sub-menu.
c. Press the 'Browse' button and select the NIM2_Release-kernel.4.5.230.bin or NIM2.4.5.230.$cc file
d. Select the NIM-2s to update in the 'Select Ethernet Hardware' window.
e. Press the 'Upload' button to start the update process.