4.6.41 - Smart Valve
Document Number: PDG-RN-2016-002
4.6.41 Software Release Notes
Release Build Date
June 13th, 2016
External Release Date
July 19th, 2016
NEW FEATURES AND CHANGES
- NIM2
- Added protected port feature. Review the special considerations section for description.(SWCHA-744)
- Added protected port feature. Review the special considerations section for description.(SWCHA-744)
Changes
- NIM2
- DAM3
- Corrected issue with power fail variables not being saved on DAM3 Modules (SWCHA-760)
DOWNLOAD LINKS
Design Pad G4
Download link | md5 checksum | Description |
DesignPadG4_Release_v4.6.41.zip | 53e18c1d050c069893948faeb73b38b5 | Design Pad G4 Install Files |
Design Pad G4 Release Package
This file contains the Fairmount Automation v4.6.41 software release. It includes software for the following products:
- Design Pad G4
- Schema Viewer G4
- FANDA Tools (SDK, Browser, OPC Server)
- FairNET OPC Server
- Firmware for:
- Smart Valve
Schema Viewer G4
Download link | md5 checksum | Description |
SchemaViewerG4_Release_v4.6.41.zip | 7491f0c09c6d82c097dfabf84652cf01 | Schema Viewer G4 Install Files |
Schema Viewer G4 Release Package
This file contains the Fairmount Automation v4.6.41 software release. It includes software for the following products:
- Schema Viewer G4
Fairmount Device Firmware
It is NOT necessary to download these file separately as they are included in the Design Pad and/or Schema Viewer v4.6.41 installation. They can be found in \Program Files\Fairmount Automation\<PROGRAM NAME> or \Program Files(x86)\Fairmount Automation\<PROGRAM NAME> (where <PROGRAM NAME> is 'Design Pad G4' or 'Schema Viewer G4').
Download link | md5 checksum | Description |
Chameleon.4.6.41.$cc | a9731363f58a8b72db879a5a83e2f273 | Firmware for all modules except NIM-2 |
NIM2L.4.6.41.$cc | 829c1f5140ae8d0202370de7a5eade5c | Firmware for NIM-2 |
FAC_2100.4.6.41.$cc | 76e01ae81de4ab55c6c990780aa688cc | Firmware for FAC-2100 regular and enhanced |
Smartvalve.4.6.41.$cc | e882b73c4c3401ece5909c0d0decebde | Firmware for Smart Valve |
SPECIAL CONSIDERATIONS
- As always, customers should ensure the updated software meets their requirements in a test environment prior to deploying in a production environment.
- Power should not be removed during the firmware update process or the device may need to be returned to the factory.
- If you are upgrading from a release prior to 4.5.264, you must review the release notes for 4.5.264_Patch 2. There are several important considerations when upgrading from pre-4.5.264 releases to release 4.6 that are included in that document..
- [NIM2] The addition of the protected port functionality limits the switching capabilities on NIM2s that do not have a schema loaded. If the NIM2 is on a failover capable wiring hub, ports 2 and 5 will be unprotected and packets can flow between those ports. All ports will be protected if the wiring hub is not failover capable. A protected port is defined as a port that will only have traffic flow between itself and unprotected ports. Protected ports cannot therefore not communicate with each other. If an existing schema is loaded, the default behavior is the same as previous firmware versions.
INSTALLATION
Installing Design Pad G4
This patch will overwrite any previous installation. If you need to keep those older versions you may manually rename the existing \Program Files\Fairmount Automation\Design Pad G4 folder to a custom name. Run the FADP.exe file in those folders to execute the previous version.
Follow these steps to install Design Pad G4:
- Transfer the G4 Software ZIP file to the local computer.
- UnZIP the file into a temporary folder on the local computer.
- Navigate to the temporary folder and open the 'Design-Pad-Installer' subdirectory.
- Run setup.exe and follow the prompts.
- Design Pad G4 will not function without a valid license.
- Any existing Design Pad G4 or G3 license will work with this patch update.
- If you do not have an existing license then, after installation is complete, follow the on-screen instructions to send the license request to Fairmount Automation. After you receive the license file, copy it into your "\Windows" or "\Program Files\Fairmount Automation\Design Pad G4" or "\Program Files(x86)\Fairmount Automation\Design Pad G4" folder.
Installing Schema Viewer G4
This patch will overwrite any previous installation. If you need to keep those older versions you may manually rename the existing \Program Files\Fairmount Automation\Schema Viewer G4 folder to a custom name. Run the FADP.exe file in those folders to execute the previous version.
Follow these steps to install Schema Viewer G4:
- Transfer the G4 Software ZIP file to the local computer.
- UnZIP the file into a temporary folder on the local computer.
- Navigate to the temporary folder and open the 'Schema-Viewer-Installer' sub-directory.
- Run setup.exe and follow the prompts.
- Schema Viewer G4 will not function without a valid license.
- Any existing Schema Viewer G4 or G3 license will work with this patch update.
- If you do not have an existing license then, after installation is complete, follow the on-screen instructions to send the license request to Fairmount Automation. After you receive the license file, copy it into your "\Windows" or "\Program Files\Fairmount Automation\Schema Viewer G4" or "\Program Files(x86)\Fairmount Automation\Schema Viewer G4" folder.
Chameleon Installation
IMPORTANT: When updating nodes that contain NIM-2 modules, the NIM-2s should be updated first and then the non-NIM-2 modules. This will ensure that the NIM-2s maintain the needed network settings to perform the update over Ethernet.
Updating NIM-2 Modules:
Ensure the NIM-2(s) are configured (IP address loaded, etc.) to be on the same network as the computer that is performing the update.
- Start Design Pad or Schema Viewer v4.6.37 or higher.
- Select 'Use Ethernet' from the Communications Menu.
To Update a Single NIM-2 from Design Pad G4 or Schema Viewer G4 v4.6.37:
- Open the Workspace and HWI associated with the NIM-2 to update.
- Choose 'Firmware Update' from the Communications Menu
- When prompted, select the NIM2L.4.6.37.$cc file
- Follow the on-screen instructions to complete the download
To Update Multiple NIM-2s from Design Pad G4 or Schema Viewer G4 v4.6.37:
- Open the Workspace associated with the NIM-2 to update.
- Right-click on the word 'Workspace' in the Workspace window and select Update Firmware (All Ethernet Hardware) from the Communications sub-menu.
- Press the 'Browse' button and select the NIM2L.4.6.37.$cc file
- Select the NIM-2s to update in the 'Select Ethernet Hardware' window.
- Press the 'Upload' button to start the update process.
Updating Non-NIM-2 Modules:
- Start Design Pad or Schema Viewer
- Choose 'Firmware Update' from the Communications Menu
- Align the IR wand to the right-most module
- Select the Chameleon.4.6.37.$cc file when requested
- Follow the on-screen instructions to complete the download
FAC-2100 Installation
- Start Design Pad or Schema Viewer
- Attach the serial cable from the computer to the COM1 port on the controller
- Choose 'Firmware Update' from the Communications Menu
- Select the FAC_2100.4.6.37.$cc file when requested
- Follow the on-screen instructions to complete the download
Smart Valve Installation
Due to the time needed to perform an IR update, it is recommended that the firmware update be done whenever possible using the Ethernet interface (a few minutes) rather than the serial IR interface (40+ minutes).
Updating Smart Valves using Ethernet:
- Ensure the Smart Valve(s) are configured (IP address loaded, etc.) to be on the same network as the computer that is performing the update.
- Start Design Pad or Schema Viewer 4.6.41 or higher.
- Select 'Use Ethernet' from the Communications Menu.
To Update a Single Smart Valve:
- Open the Workspace and HWI associated with the Smart Valve to update.
- Choose 'Firmware Update' from the Communications Menu
- Press the 'Browse' button and select the Smartvalve.4.6.41.$cc file
- Keep 'Preserve network settings after reboot' checked.
- Press the Upload button to start the update process.
To Update Multiple Smart Valves:
- Open the Workspace associated with the Smart Valves to update.
- Right-click on the word 'Workspace' in the Workspace window and select Update Firmware (All Ethernet Hardware) from the Communications sub-menu.
- Press the 'Browse' button and select the Smartvalve.4.6.41.$cc file
- Select the Smart Valves to update in the 'Select Ethernet Hardware' window.
- Keep 'Preserve network settings after reboot' checked.
- Press the 'Upload' button to start the update process.
During the firmware update process, any existing Smart Valve program will be erased. If desired, reprogram valve by opening the desired program and selecting Program Hardware (reset schemas) from the Communications Menu.
Updating the Smart Valves using IR:
- Start Design Pad or Schema Viewer
- Open the Workspace and HWI associated with the Smart Valve to update.
- Choose 'Firmware Update' from the Communications Menu
- Remove the IR blocking plug (if installed) and align the IR wand to the actuator
- Select the Smartvalve.4.6.41.$cc file when requested
- Follow the on-screen instructions to complete the download
During the firmware update process, any existing Smart Valve program will be erased. If desired, reprogram valve by opening the desired program and selecting Program Hardware (reset schemas) from the Communications Menu.