Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Document Number: PDG-RN-2016-002

4.6.41 Software Release Notes

Release Build Date

June 13th, 2016

External Release Date

July 19th, 2016

NEW FEATURES AND CHANGES

  • NIM2
    • Added protected port feature.  Review the special considerations section for description.(SWCHA-744)

Changes

  • NIM2
    • Corrected issue in binary comm channel receiver which would cause messages to stop being received.  (SWCHA-756 )
    • Added process to monitor the ssh daemon and restart if necessary.  No issues have been reported.  ( SWCHA-697)
  • DAM3
    • Corrected issue with power fail variables not being saved on DAM3 Modules (SWCHA-760)


 

DOWNLOAD LINKS

Design Pad G4

Download link

md5 checksum

Description

DesignPadG4_Release_v4.6.41.zip53e18c1d050c069893948faeb73b38b5

Design Pad G4 Install Files

Design Pad G4 Release Package

This file contains the Fairmount Automation v4.6.41 software release. It includes software for the following products:

  • Design Pad G4
  • Schema Viewer G4
  • FANDA Tools (SDK, Browser, OPC Server)
  • FairNET OPC Server
  • Firmware for:
    • Smart Valve

Schema Viewer G4

Download link

md5 checksum

Description

SchemaViewerG4_Release_v4.6.41.zip7491f0c09c6d82c097dfabf84652cf01

Schema Viewer G4 Install Files

Schema Viewer G4 Release Package

This file contains the Fairmount Automation v4.6.41 software release. It includes software for the following products:

  • Schema Viewer G4

 

Fairmount Device Firmware

It is NOT necessary to download these file separately as they are included in the Design Pad and/or Schema Viewer v4.6.41 installation. They can be found in \Program Files\Fairmount Automation\<PROGRAM NAME> or \Program Files(x86)\Fairmount Automation\<PROGRAM NAME> (where <PROGRAM NAME> is 'Design Pad G4' or 'Schema Viewer G4').


 Download link

md5 checksum

Description

Chameleon.4.6.41.$cca9731363f58a8b72db879a5a83e2f273

Firmware for all modules except NIM-2

NIM2L.4.6.41.$cc829c1f5140ae8d0202370de7a5eade5c

Firmware for NIM-2

FAC_2100.4.6.41.$cc76e01ae81de4ab55c6c990780aa688cc

Firmware for FAC-2100 regular and enhanced

Smartvalve.4.6.41.$cce882b73c4c3401ece5909c0d0decebde

Firmware for Smart Valve

 

SPECIAL CONSIDERATIONS

  1. As always, customers should ensure the updated software meets their requirements in a test environment prior to deploying in a production environment.
  2. Power should not be removed during the firmware update process or the device may need to be returned to the factory.
  3. If you are upgrading from a release prior to 4.5.264, you must review the release notes for 4.5.264_Patch 2.  There are several important considerations when upgrading from pre-4.5.264 releases to release 4.6 that are included in that document..
  4. [NIM2] The addition of the protected port functionality limits the switching capabilities on NIM2s that do not have a schema loaded.  If the NIM2 is on a failover capable wiring hub, ports 2 and 5 will be unprotected and packets can flow between those ports.  All ports will be protected if the wiring hub is not failover capable.  A protected port is defined as a port that will only have traffic flow between itself and unprotected ports.  Protected ports cannot therefore not communicate with each other.  If an existing schema is loaded, the default behavior is the same as previous firmware versions.

INSTALLATION

Installing Design Pad G4

This patch will overwrite any previous installation. If you need to keep those older versions you may manually rename the existing \Program Files\Fairmount Automation\Design Pad G4 folder to a custom name. Run the FADP.exe file in those folders to execute the previous version.

Follow these steps to install Design Pad G4:

  1. Transfer the G4 Software ZIP file to the local computer.
  2. UnZIP the file into a temporary folder on the local computer.
  3. Navigate to the temporary folder and open the 'Design-Pad-Installer' subdirectory.
  4. Run setup.exe and follow the prompts.
  5. Design Pad G4 will not function without a valid license.
    1. Any existing Design Pad G4 or G3 license will work with this patch update.
    2. If you do not have an existing license then, after installation is complete, follow the on-screen instructions to send the license request to Fairmount Automation. After you receive the license file, copy it into your "\Windows" or "\Program Files\Fairmount Automation\Design Pad G4" or "\Program Files(x86)\Fairmount Automation\Design Pad G4" folder.

Installing Schema Viewer G4

This patch will overwrite any previous installation. If you need to keep those older versions you may manually rename the existing \Program Files\Fairmount Automation\Schema Viewer G4 folder to a custom name. Run the FADP.exe file in those folders to execute the previous version.

Follow these steps to install Schema Viewer G4:

  1. Transfer the G4 Software ZIP file to the local computer.
  2. UnZIP the file into a temporary folder on the local computer.
  3. Navigate to the temporary folder and open the 'Schema-Viewer-Installer' sub-directory.
  4. Run setup.exe and follow the prompts.
  5. Schema Viewer G4 will not function without a valid license.
    1. Any existing Schema Viewer G4 or G3 license will work with this patch update.
    2. If you do not have an existing license then, after installation is complete, follow the on-screen instructions to send the license request to Fairmount Automation. After you receive the license file, copy it into your "\Windows" or "\Program Files\Fairmount Automation\Schema Viewer G4" or "\Program Files(x86)\Fairmount Automation\Schema Viewer G4" folder.

Chameleon Installation

IMPORTANT:  When updating nodes that contain NIM-2 modules, the NIM-2s should be updated first and then the non-NIM-2 modules. This will ensure that the NIM-2s maintain the needed network settings to perform the update over Ethernet.

Updating NIM-2 Modules:

Ensure the NIM-2(s) are configured (IP address loaded, etc.) to be on the same network as the computer that is performing the update.

  1. Start Design Pad or Schema Viewer v4.6.37 or higher.
  2. Select 'Use Ethernet' from the Communications Menu.

To Update a Single NIM-2 from Design Pad G4 or Schema Viewer G4 v4.6.37:

  1. Open the Workspace and HWI associated with the NIM-2 to update.
  2. Choose 'Firmware Update' from the Communications Menu
  3. When prompted, select the NIM2L.4.6.37.$cc file
  4. Follow the on-screen instructions to complete the download

To Update Multiple NIM-2s from Design Pad G4 or Schema Viewer G4 v4.6.37:

  1. Open the Workspace associated with the NIM-2 to update.
  2. Right-click on the word 'Workspace' in the Workspace window and select Update Firmware (All Ethernet Hardware) from the Communications sub-menu.
  3. Press the 'Browse' button and select the NIM2L.4.6.37.$cc file
  4. Select the NIM-2s to update in the 'Select Ethernet Hardware' window.
  5. Press the 'Upload' button to start the update process.

Updating Non-NIM-2 Modules:

  1. Start Design Pad or Schema Viewer
  2. Choose 'Firmware Update' from the Communications Menu
  3. Align the IR wand to the right-most module
  4. Select the Chameleon.4.6.37.$cc file when requested
  5. Follow the on-screen instructions to complete the download 

FAC-2100 Installation

  1. Start Design Pad or Schema Viewer
  2. Attach the serial cable from the computer to the COM1 port on the controller
  3. Choose 'Firmware Update' from the Communications Menu
  4. Select the FAC_2100.4.6.37.$cc file when requested
  5. Follow the on-screen instructions to complete the download

 

Smart Valve Installation

Due to the time needed to perform an IR update, it is recommended that the firmware update be done whenever possible using the Ethernet interface (a few minutes) rather than the serial IR interface (40+ minutes).

Updating Smart Valves using Ethernet:

  1. Ensure the Smart Valve(s) are configured (IP address loaded, etc.) to be on the same network as the computer that is performing the update.
  2. Start Design Pad or Schema Viewer 4.6.41 or higher.
  3. Select 'Use Ethernet' from the Communications Menu.

To Update a Single Smart Valve:

  1. Open the Workspace and HWI associated with the Smart Valve to update.
  2. Choose 'Firmware Update' from the Communications Menu
  3. Press the 'Browse' button and select the Smartvalve.4.6.41.$cc file
  4. Keep 'Preserve network settings after reboot' checked.
  5. Press the Upload button to start the update process.

To Update Multiple Smart Valves:

  1. Open the Workspace associated with the Smart Valves to update.
  2. Right-click on the word 'Workspace' in the Workspace window and select Update Firmware (All Ethernet Hardware) from the Communications sub-menu.
  3. Press the 'Browse' button and select the Smartvalve.4.6.41.$cc file
  4. Select the Smart Valves to update in the 'Select Ethernet Hardware' window.
  5. Keep 'Preserve network settings after reboot' checked.
  6. Press the 'Upload' button to start the update process.

During the firmware update process, any existing Smart Valve program will be erased. If desired, reprogram valve by opening the desired program and selecting Program Hardware (reset schemas) from the Communications Menu.

Updating the Smart Valves using IR:

  1. Start Design Pad or Schema Viewer
  2. Open the Workspace and HWI associated with the Smart Valve to update.
  3. Choose 'Firmware Update' from the Communications Menu
  4. Remove the IR blocking plug (if installed) and align the IR wand to the actuator
  5. Select the Smartvalve.4.6.41.$cc file when requested
  6. Follow the on-screen instructions to complete the download

During the firmware update process, any existing Smart Valve program will be erased. If desired, reprogram valve by opening the desired program and selecting Program Hardware (reset schemas) from the Communications Menu.

 

 

 

 

 

 

 

 

 

  • No labels