- NIM2
- DAM3
- Corrected issue with power fail variables not being saved on DAM3 Modules (SWCHA-760)
DOWNLOAD LINKS
Design Pad G4
Download link | md5 checksum | Description |
DesignPadG4_Release_v4.6.41.zip | 53e18c1d050c069893948faeb73b38b5 | Design Pad G4 Install Files |
Design Pad G4 Release Package
...
- Design Pad G4
- Schema Viewer G4
- FANDA Tools (SDK, Browser, OPC Server)
- FairNET OPC Server
- Firmware for:
- Smart Valve
Schema Viewer G4
Download link | md5 checksum | Description |
SchemaViewerG4_Release_v4.6.41.zip | 7491f0c09c6d82c097dfabf84652cf01 | Schema Viewer G4 Install Files |
Schema Viewer G4 Release Package
This file contains the Fairmount Automation v4.6.41 software release. It includes software for the following products:
- Schema Viewer G4
...
Fairmount Device Firmware
It is NOT necessary to download these file separately as they are included in the Design Pad and/or Schema Viewer v4.6.41 installation. They can be found in \Program Files\Fairmount Automation\<PROGRAM NAME> or \Program Files(x86)\Fairmount Automation\<PROGRAM NAME> (where <PROGRAM NAME> is 'Design Pad G4' or 'Schema Viewer G4').
Download link | md5 checksum | Description |
Chameleon.4.6.41.$cc | a9731363f58a8b72db879a5a83e2f273 | Firmware for all modules except NIM-2 |
NIM2L.4.6.41.$cc | 829c1f5140ae8d0202370de7a5eade5c | Firmware for NIM-2 |
FAC_2100.4.6.41.$cc | 76e01ae81de4ab55c6c990780aa688cc | Firmware for FAC-2100 regular and enhanced |
Smartvalve.4.6.41.$cc | e882b73c4c3401ece5909c0d0decebde | Firmware for Smart Valve |
...
SPECIAL CONSIDERATIONS
- As always, customers should ensure the updated software meets their requirements in a test environment prior to deploying in a production environment.
- Power should not be removed during the firmware update process or the device may need to be returned to the factory.
- If you are upgrading from a release prior to 4.5.264, you must review the release notes for 4.5.264_Patch 2. There are several important considerations when upgrading from pre-4.5.264 releases to release 4.6 that are included in that document..
- [NIM2] The addition of the protected port functionality limits the switching capabilities on NIM2s that do not have a schema loaded. If the NIM2 is on a failover capable wiring hub, ports 2 and 5 will be unprotected and packets can flow between those ports. All ports will be protected if the wiring hub is not failover capable. A protected port is defined as a port that will only have traffic flow between itself and unprotected ports. Protected ports cannot therefore not communicate with each other. If an existing schema is loaded, the default behavior is the same as previous firmware versions.
...
- Start Design Pad or Schema Viewer
- Attach the serial cable from the computer to the COM1 port on the controller
- Choose 'Firmware Update' from the Communications Menu
- Select the FAC_2100.4.6.37.$cc file when requested
- Follow the on-screen instructions to complete the download
...
Smart Valve Installation
Due to the time needed to perform an IR update, it is recommended that the firmware update be done whenever possible using the Ethernet interface (a few minutes) rather than the serial IR interface (40+ minutes).
...
During the firmware update process, any existing Smart Valve program will be erased. If desired, reprogram valve by opening the desired program and selecting Program Hardware (reset schemas) from the Communications Menu.